High Efficiency Gas Steam Boiler. 1.8 - 3.9m³ Water Volume Gas Fired Boiler, High Efficiency Gas Boiler OHSAS Approved. New Condition Energy Saving Gas Boilers, Gas Condensing Boiler Large Heating Surface. Three Passes High Efficiency Gas Steam Boiler 95% Thermal Efficiency. 1.25MPa Work Pressure Gas System Boiler ON - OFF Computer Control
Get a Quote2019-9-11·5 ton natural gas three pass steam boiler for sale. posted:2019-08-15 We sell 5 ton natural gas steam boiler, which is our WNS series three-pass fire tube boiler. Natural gas steam boiler is an environmentally friendly boiler, which is easy to operate and widely used, and is mostly used in industry.
Get a QuoteIndustrial Gas Fired Boiler, Oil Fired Boiler, Gas amp; Oil . 2019-4-26 · As a leader in industrial boiler manufacturers, 20-90 Ton Coal Boiler offers 0.5-130 ton with pressure up to 9.81MPa / 98.1bar industrial gas and oil steam boilers, hot water boilers and power plant boilers.
Get a Quote2017-11-30·2 5 ton capacityhour oil gas steam boiler in bangladesh. 2 5 ton capacityhour oil gas steam boiler in bangladesh. Posted On : 2017-08-20 Published By : Jenny Wu. Quick inquiry: I need the quotation of, the fuel is, the capacity is . My Name is, My Email is
Get a Quote2020-3-18·Oil Gas Fired 5 Ton Steam Boiler Price. 5ton Oil fired steam boiler supplier in Pakistan A fire tube gas fired boiler can burn natural gas, city gas, propane, LPG, etc. Propane fired 5 ton steam boiler is fire tube horizontal one, used in small and middle 5 Ton HFO Boiler
Get a Quote0.5 ton electric heating steam boiler and 1 ton gas steam boiler are about to be sent to Germany
Get a Quote2019-7-16·Gasamp;Oil Fired Steam Boiler. Capacity: 1-130 ton/h. Pressure: 0.7 - 2.5 MPa. Thermal efficiency: above 98%. Fuel: natural gas, oil, diesel. Read more
Get a Quote2019-3-15·5 ton gas fired steam boiler can produce 5 ton steam per hour which can meet most medium-large size plant requirements. Here, the writer will introduce WNS steam boiler for fish meal plant. The reasons are as following:
Get a Quote75 ton gas fired steam boiler parameters. Model: ZG-75/3.82-Q ZG-75/10.5-Q. Rated steam capacity: 75 ton/hr. Rated steam pressure: 3.82 MPa 10.5 MPa. steam temperature: 450 510 Feed water temperature: 104 110 Fuel type: natural gas, coke oven gas, blast furnace gas. 75 ton gas fired steam boiler price
Get a Quote6 ton natural gas steam boiler. How much natural gas is required to produce 1 ton of steam? Natural gas is made due to anaerobic fermentation. In the early ages of the world, plants where being fermented, but the gas was unable to escape out of the ground.
Get a Quote2020-3-14·Characteristics about the boiler: 1.Fuel:Natural gas,LPG,CNG,LNG,diesel oil,heavy oil,city gas,dual fuel,etc. 2.The steam boiler have horizontal structure,so the thermal efficiency is higher; 3.It has the three returns design, so exhausted smoke temperature is low;
Get a Quote700 bhp 10 bar 10 ton 15 ton natural gas steam boiler. 1.Fire tube 3 pass oil gas steam boiler. 2.Combustion chamber with large volume; 3.Spirally corrugated tube, strengthening heat transfer and eliminating welding stress; 4..PLC Intelligent Control system,full-automatic steam boiler 5.High efficiency,over 95%.
Get a QuoteWUXI BOILERS CO.,LTD is the government designated enterprise of A-grade boilers,BRII.grade pressure contaiiners and ASME "S""U" manufacturing icense that is approved by the general Administration of quality supervision,Inspection and quarantine of the people's republic of China.
Get a Quote2019-3-15·5 ton Steam Boiler to burn Sunflower Husks. An clients from Bolivia, contacted with our service staff online, he wanted to know the price of 5 ton biomass steam boiler burning sunflower husks. Our Bolivia client owned a food factory which needs 5 ton steam per hour in food process.
Get a Quote2013-4-1·Industrial steam boiler,Coal Boiler,Gas steam boiler,oil steam boiler,thermal oil boiler,thermal fluid heater.1 ton steam boiler,2 ton steam boiler,3 ton steam boiler,4 ton steam boiler,5 ton steam boiler,6 ton steam boiler,8 ton steam boiler,10 ton steam boiler.
Get a QuoteCopyright © 2019.Boiler Supplier All rights reserved.
The advantages of horizontal resolution horizontal gas 5 ton steam boiler steam boiler gas with a higher degree of automation world automatic burner as the primary combustion equipment. There are heating and hot water boiler bath for two purposes. Hot water boiler by circulating hot water circulation pump hot water holding tank, the tank hot water heating cycle can be achieved bath object; hot water boiler by circulating hot water circulation pump heating conduit, through the heat sink (radiator) people can achieve heating requirements; hot water boiler and hot water circulating pump with heat exchanger can be achieved bathing and heating dual function. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass hot water boiler, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. Burner combustion process is controlled by a controller of a more advanced combustion process. The present invention may be implemented fuel boiler functions required for normal combustion, and in a normal state, the automatic stop accident protection state and the abnormal situation, and equipped with a temperature controller and a respective proportional pressure regulator, high low temperature indication , indicating overpressure is adjusted. Level 1 to ensure that the water level fluctuation within the normal range, supporting equipment, advanced comprehensive technical performance. 2. The water circulation simple, rational structure compression member, to ensure safe operation under the conditions of the water quality. 3. The overall structure is reasonable, compact, fast loading and qualified factory. This product manufactured consists of three parts: the host, chimney and duct system of a boiler, wherein the host and manufactured by the factory chimneys, pipelines and valves and the host supporting instrumentation free installation, and the stack may be assembled on-site host. It may be on-site air source, power supply, water connection is detected. Installation cycles are significantly reduced. 4. Advanced design performance. Boilers host belongs to the whole structure. Burner mounted on the front cover of smoke, the main body is provided with a heating surface and the combustion chamber. The present invention has a reasonable structure, compact, low consumption of steel, biasing bellows tank furnace, using new lightweight thermal insulation material, packaging using a color sheet, a rectangular parallelepiped packaging advantages boiler performance, weight, frame size and appearance are much better than the domestic capacity products. Boiler feed water device is provided on the right side of the base boiler boiler, combining it with the host, you do not need a further base.
First, when the flue temperature dropped to below 50 ℃ Solution: Check the tail may enter the flue if heated, while the flue thoroughly remove soot. No burning flue tail, can be re-started ignition; if burning, should be replaced, repaired burning member. Second, the combustion chamber when the negative pressure is too large Solution: When the exhaust gas temperature close to the temperature of the injected steam, or less than 150 deg.] C over 1 hour and stable, open the inspection hole inspection; after inspection after confirming the fire source, before start the fan ventilation. Third, shutdown or fire, air gun valve ajar solutions: reinforcing and electric 5 ton steam boiler feed water drainage, or open the valve economizer recirculation tube to protect the economizer is not burning. Fourth, Kai, during shutdown lower furnace temperature, a solution of unburned fuel in the furnace: extinguishing device immediately put into vapor, carbon dioxide or other devices off fire. Five burning improperly adjusted, with insufficient wind or with the wind unreasonable Solution: Close the flue duct and baffle around the door opening, start sending prohibited, induced draft fan. These are the methods of electric heating steam boiler fast boiler to provide you with the handling of soot in the chimney, if you use electric steam boilers, with more than five can control their own boiler equipment need to be cleared up the flue, and select the appropriate method .
The use of central heating hot water boiler is the best choice for winter heating in northern China. Shanxi Province is located in Chang Darrow Heating Co., Ltd. mainly provides heating and post-service maintenance of heating equipment, heating clients involved in enterprises and institutions, office buildings, residential housing and a variety of commercial and other entertainment venues. With the wide blue sky covered Battle of the project, China's gradual increase in the proportion of heating for cleaning, heating, Ltd. Dalong Chang respond positively to the call of national policy, high pollution intensity wishing previously used, low thermal efficiency of coal-fired boiler to replace the traditional use hot water boiler clean fuel. After comparing many boiler manufacturers, choosing the optimal selection, determined and professional cooperation parties do fast boiler fuel boiler cleaning equipment. Providing a fast side 35 MW gas tube hot water boiler (SZS35-1.6-Y.Q) according to their actual needs.
Commissioning of Boiler gas boiler commissioning must be carried out after the hydrostatic test. Before commissioning, should be a comprehensive inspection of each furnace parts, electronic control devices, wiring, etc. are normal, water supply, oil furnace if opened, electrical contacts are in the set position. 1, depending on the size of the fuel consumption, the initial damper, the hydraulic pressure. 2, the power is turned on, the power switch to open the cabinet, the water pump starts furnace, (if the pump is rotated into the anhydrous, pump purge valve is opened, the air exhaust pump). 3, control checks whether the normal water level electrode. 4, check the burner operation is normal. Starter burner starts combustion when the water level rose to a predetermined level, the start of combustion is normal to observe: Start no vibration noise, stable combustion, no smoke, orange yellow flame, burning bright clear. Otherwise, to make the appropriate adjustment (refer to burner instructions). Note: The oil pressure between 0.8 ~ 1.0Mpa, after a good tune, do not easily change, oil pressure is too high or too low have an effect on burner performance life. 5, check the pressure gauge pointer swing is smooth, with or without loosening stuck. 6, whether the discharge check valve is set at the set pressure steam: Pressure controller first maximum working pressure, a safety valve is adjusted to the set pressure higher than 0.05MPa, when the furnace pressure was raised to whether the exhaust pressure setting, if exhaust , pulling the safety valve a few times, and try again, if not enough to deal with safety valve to adjust. Pressure relief valve setting: boiler rated pressure + 0.03MPa. 7, check the electrical contacts of the operation: When the pressure is raised to the maximum working pressure (not exceed the rated working pressure), should stop burning, open the safety valve blowing off steam, the pressure to a minimum operating pressure (maximum operating pressure is generally lowest set to 0.10MPa), combustion burner should be restarted. Note: When the adjustment screw should slow, especially when the pointer approaches the end, otherwise, damage the screw off the wire.