We're well-known as one of the leading heavy oil horizontal steam boiler manufacturers and suppliers in China for our quality products and low cost. Welcome to buy the best heavy oil horizontal steam boiler for sale from our factory and check prices with us.
Get a QuoteGas Boiler, Steam Boiler, Coal Boiler manufacturer / supplier in China, offering Columbia 1t 2t 4t 6t 8t Automatic Solid Fuel Boilers, Fully Equipped 10t/H Capacity Horizontal Type Wood Pellet Boiler, High Quality Packaged Coal Boiler Automatic Steam Boiler on Coal and so on.
Get a QuoteChina Stainless Steel Central Combustion Oil Fired Boiler, Find details about China LPG Fired Steam Boiler, Steam Heating Boiler from Stainless Steel Central Combustion Oil Fired Boiler - Qingdao Shengli Boiler
Get a QuoteLight Oil Fired Boiler Price. Oil Gas Fired Boiler. Search for: Search. China 6ton Heavy Oil Boiler Manufacturers. Posted on January 12, 2019 Author Light Oil Fired Boiler Price 0. Previous Post China Best Selling Electric Steam Boiler for Sale. Next Post Industrial Oil Gas Steam Boiler with Moderate Price.
Get a QuoteQuality steam boiler,hot water boiler,coal fired boiler for sale, steam boiler,hot water boiler,coal fired boiler amp; gas-firedboiler provided by China Suppliers - Henan Yuanda Boiler Co.,ltd.
Get a QuoteFree Online Consultation; School Atmospheric Pressure Boiler Supplier. School Atmospheric Pressure Water Tube Boiler . School Atmospheric Steam Boiler For Sale Reasonable Price Fire Tube Heavy Oil Diesel Fired 5 ton Diesel boiler is an ideal heating equipment for
Get a Quote2019-3-20·Steam boiler. ZG steam boiler passed the ASME certification, and reached the IBR standards. Available for horizontal steam boiler capacities up to 35 t/hr, 2.45Mpa and 194°C, 100% membrane wall fabrication provides a fully water-cooled furnace with zero gas by pass and inherently lower emissions, Two years warranty on our headered front and rear membrane walls.
Get a QuoteChina Yuanda Boiler Industrial Oil Gas Steam Boiler price . Focous On 1 ton to 20 ton steam boiler. boiler1956hotmail.com 250 bhp 4 ton Heavy Oil Steam Boiler. 100 psi Fire tube 125 hp Oil Fired Steam Boiler. Factory:Xihua County,Henan Province,China +86 150 9345 0119 +86 -150 9345 0119. boiler1956hotmail.com. Latest News. 2 ton Oil
Get a Quoteheavy oil fired water tube boiler | Price of Industrial Boiler. Heavy Oil Fired Water Tube Steam Boiler SiTong The structure of heavy oil fired water tube boiler is arranged as drum longitudinal type D shape, its quickly assembled boiler with water tubes, has the China Heavy Oil Fired
Get a Quote3ton Industrial Gas Fired China Good Oil Steam Boilers Price, Find details about China Gas Boiler, Steam Boiler from 3ton Industrial Gas Fired China Good Oil Steam Boilers Price -
Get a Quote1-20Ton Heavy Oil Steam Boiler For Sale. January 29, 2019, Pakistan-lng-boiler-for-sale, Leave a comment. 5 Ton Steam Boiler For Sale, Wholesale amp; Suppliers Alibaba. About product and suppliers: Alibaba.com offers 1,867 5 ton steam boiler for sale products.
Get a Quotefuel heavy oil boiler. 20010^4 Kcal/h best price industrial fire tube natural gas lpg lng diesel heavy fuel oil fired steam boiler. China combined gas fired heavy oil fuels hot water boiler dealer. US$12,709.00-US$138,000.00
Get a Quote2020-3-18·China New Industrial LNG LPG Oil Gas Fired Low Nox . Oil Steam Boiler, Gas Boiler, Oil Boiler manufacturer / supplier in China, offering New Industrial LNG LPG Oil Gas Fired Low Nox Steam Boiler Hot Water Boiler, High Heating Efficiency Dual Fuel Steam Boilers, High Output 6 Tph Automatic Chain Grate Stoker Coal Boiler and so on.
Get a QuoteQingdao Xingfu Boiler Thermal Power Equipment Co., Ltd. is established in 1981, located in Qingdao, one major seaport of China. We are specialized in manufacturing A level Boilers, BRI level pressure vessels and the waste tyre and plastic pyrolysis equipment, authorized by the General Administration of Quality Supervision, Inspection and Quarantine of the Peoples Republic of China.
Get a Quoteheavy oil fired hot water boiler manufacturers. Boiler is the Asia's leading manufacturer of oil gas boilers,industrial steam boilers,hot water boilers,firetube boilers, watertube boilers,high/low pressure boilers as well as high efficiency low nitrogen condensing boilers and horizontal/vertical heating boilers for . industrial heavy oil fired condensing water boilers in oceania
Get a QuoteCopyright © 2019.Boiler Supplier All rights reserved.
Gas introduced gas steam boiler price in china steam boiler stop sign Profile: natural gas steam boiler is a steam boiler gas, natural gas steam boiler with natural gas as fuel, the combustion in the furnace heat put out by heating the pot water, and allowed to vaporized into steam energy conversion device. Water pan (drum) is continuously released from the combustion of a gaseous fuel energy to heat the furnace temperature is increased and produce steam under pressure. Since the boiling point of water increases with increased pressure, the pot is sealed, the expansion of water vapor generated inside the pressure limited thermodynamic formed, strictly speaking, the steam boiler is heated in water at constant pressure saturated steam drum regasification water formed, is widely used as an energy source. Protection device: (1) protect the boiler water a boiler water level gauge plate supporting one to two, should always be compared with each other, inconsistent findings indicate that shall be corrected immediately. Class water level should be flushed, to determine their true level. While the water level comes electrode rod can accurately capture level signal to an alarm or a pump control. (2) steam pressure protection pressure controller: selection of high sensitivity of the pressure controller, the pressure is high, or low levels of signal to the electrical switches, other control lines or automatic control chain protection. Using pressure controllers and electrical contacts, the vapor pressure can overpressure alarm; single adjustable pressure controller or dual fire burning fire the actual operating pressure. Safety valve: safety valve is the last line of defense to protect the boiler, the boiler pressure exceeds the limit, according to the set pressure relief valve design with the school, the exhaust steam pressure relief, to ensure the normal operation of the boiler. (3) having a burner flame protection flame protection inlet means, combustion function is to detect, when the ignition failure or extinguish combustion middle, immediately off the burner into the oil (gas) solenoid valve, the blower continues to operate at this time, the furnace was purged combustible residual gas, after 20 to 30 seconds purge, and various auxiliary blowers automatically cut off power, the boiler operation stops. (4) self-locking power failure protection case, the boiler shutdown immediately burst self-locking power interruption, if the current power is restored, the boiler will not start at any time, you must reset release self-locking, to re-start the ignition. Editing boiler ignition procedures: 1. Check operation and (or) shift recording. 2, inspection, examination boiler, external. 3, check the main safety accessories. Safety valve, water gauge, pressure gauge, to be tight, reliable and sensitive. 4, check the water treatment equipment. 5, inspection equipment and soda water supply system pipe. Adjust the valves as required to start. 6. Check the oil supply equipment. After the above inspection qualified, you can start the boiler. Note: The boiler is a high-temperature, high-pressure thermal equipment, is one of special equipment, widely used in government agencies, public companies and all walks of life, it is dangerous and special equipment. Event of an accident involving public safety, it will cause huge losses to the state and people's lives and property. For public safety, people's lives and property safety, according to the State Council, "Regulations on Safety Supervision of Special Equipment", the boiler should use full attention the following matters: 1, should be accompanied by safety technical specifications of the factory boiler design documents, product quality certification, safety and the use and maintenance instructions, supervision and inspection certificate (safety supervision, inspection and performance certificate). 2, boiler installation, maintenance, alteration. Engaged in the installation of the boiler, maintenance, renovation of the unit shall obtain special equipment installation and maintenance certificates issued by the Provincial Quality and Technical Supervision, before engaging in the boiler installation, maintenance, alteration. Construction unit before construction will be prepared for installation, maintenance, alteration in writing inform the special equipment safety supervision and management department of the municipality or district, and will start informing sent to the local county level Quality and Technical Supervision for the record, told immediately after construction. 3, inspection of boiler installation, maintenance, transformation. After construction, the construction unit To State Quality and Technical Supervision of Special Equipment Inspection and hydrostatic testing of the boiler installation supervisory inspection declaration. After passing by the State Quality and Technical Supervision, State Special Equipment Inspection, County of Quality and Technical Supervision involved in overall acceptance. 4, registration boiler. After the boiler inspection, the use of units must be in accordance with the "special equipment registration and use of management rules", fill "boiler (census) Registration Form", the State Quality and Technical Supervision to register and obtain a "registration certificate to use special equipment safety . " 5, operation of the boiler. Boiler operation must be performed by trained and qualified to obtain "special equipment operator certificate" certified personnel to operate, must strictly abide by the rules and eight systems, six record. 6, check the boiler. Periodic inspection of boiler once a year, not be used without safety periodic inspection of boilers. Safety accessories safety valve of the boiler regular inspection once a year, pressure gauge biannually verified, may not be used without the periodic inspection of the safety accessories. 7, non-pressure boilers will be installed for the boiler pressure. Do not use water level gauge, safety valve, pressure gauge three safety accessories insufficiency boiler.
Heilongjiang provincial government to respond positively to win the Battle of Blue Sky policy action plan issued by the Ministry of ecology and environmental protection, recently issued "on the issuance of Heilongjiang Province to win the Battle of the sky three-year action plan" (hereinafter referred to as "Plan").
"Plan" requirements, as of 2020, the province of sulfur dioxide, nitrogen oxide emissions are decreased year on year in 2015 to more than 11%; PM2.5 did not meet the concentration level and above cities fell year on year in 2015 to more than 15% , and above the level of urban air quality days ratio reaches 88%, and more heavily polluted year 2015 the number of days decreased the ratio of 15% or more.
"Plan" put forward 47 specific measures from nine aspects, namely: to adjust and optimize the industrial structure, promote the formation of green development; speed up the adjustment of energy structure, build clean energy systems; actively adjust the transport structure, the development of green transportation system; optimal adjustment of land structure, promote urban and rural non-point source pollution control; strengthening regional joint prevention and control, to effectively deal with heavy pollution weather; sound regulations and standards, improve environmental economic policies; for strengthening the infrastructure, strict environmental enforcement inspectors; clear responsibility for implementation of the parties, strict accountability assessment ; strengthen information disclosure, mobilize the whole society to participate.
"Plan" requirements, strictly control the total coal consumption.
1, in accordance with the focus on the use of coal and clean use of principles, focusing on reduction of non-coal for electricity, coal and oil to promote alternative energy by 2020, cities (prefectures) Coal accounts for the proportion of energy consumption fell by 1.5% compared with 2015.
2, bulk coal strengthening control, adjustment and optimization of high-pollution fuel combustion zone ban, the use of high-pollution fuel control, bulk coal alternative strengthening. Clean steadily heating, promoting the use of clean coal and clean energy.
3, to carry out comprehensive improvement of coal-fired boilers, to carry out level and above urban area 10 steam tons / hour coal-fired boilers and "clear" action. Improve energy efficiency, we continue to implement the dual-control operations total energy consumption and intensity.
4, accelerate the development of clean energy, and orderly development of wind power, biomass power generation and actively promote the construction of hydropower development focus on the promotion of river basins, and strengthen the development and utilization of geothermal energy exploration, increase renewable energy consumptive efforts.
Tail secondary combustion flue how to deal with the phenomenon of a sharp increase in rear of the boiler flue secondary combustion flue temperature location and later. 2, the furnace, the flue abrupt change in negative pressure, flue gas is not tight at the smoke, the Mars. 3, air preheater large current swing bearing housing temperature, severe Jam occurs. 4, air preheater fire alarm issue. 5, steam temperature, economizer outlet water temperature, the air temperature rises abnormally. 6, induced draft fan vanes automatically open a large, Fan current rise. 7, as the combustion side, both sides of the smoke temperature difference increases. Reason 1, through the coarse fine grinding coal, coal poor uniformity, improper adjustment of combustion, combustion of fuel is insufficient, serious mechanical incomplete combustion, and high levels of combustible ash accumulated in the back pass. 2, an oil burner or an oil poor atomization, so that unburned droplets deposited in the flue. 3, prolonged low load operation of boiler, the furnace temperature is too low or too small amount of excess air resulting in incomplete combustion of coal or oil accumulated in the tail. 4, after the shutdown of the fuel leakage into the furnace and accumulates or after shutdown and to insufficient MFT furnace purge unburnt coal or oil accumulation at the end of the tail. 5, soot blower failure, long-term put into operation is not normal. 1 process, when a slight secondary combustion, exhaust gas temperature does not rise within 20 ℃ normal smoking temperature should be checked immediately paragraphs, the combustion site and judge whether the secondary steam soot blowing. (When the exhaust gas temperature rises to 250 ℃) 2, the operation of the back pass and then generating boiler combustion boiler operation should be stopped immediately, immediately stop sending, ID fan and turn off all the smoke and steam soot blowing air damper fire. 3, if the economizer afterburning, until the storage tank level control valve blocking off without pressure, flow rate of feed pump motor start 150t / h Sheung be cooled. 4, air preheater heating surface of the secondary combustion air preheater normal operation, normal operation of the air pre-heater holder; air preheater Jam occurs, the main drive motor and the auxiliary drive motor trip, contact maintenance manual plate moving continuous air preheater rotor. Soot blowing steam into air preheater for extinguishing, into the air preheater for fire extinguishing can not be extinguished. 5, the economizer outlet water temperature close to the inlet temperature (at the economizer secondary combustion), the air preheater inlet gas temperature, exhaust gas temperature, the hot air temperature is lowered to less 80 ℃, each one hole, and the hole is no longer Mars smoke and soot blowing steam stops coming out after water or fire. Open hole inspection manhole and inspection to confirm the secondary combustion goes out, after the flue vent door open to drain water inside the smoke flue opening for ventilation air damper. 6, to be re-combustion is resolved, the flue temperature does not rise and fall when stabilized, before slow regulation of the air, smoke baffle, the necessary air cooling and purging.
Use should pay attention to the problem of steam boiler price in china pressure gauge. Rated steam pressure of less than 2.45MPa steam boiler, a manometer accuracy no less than 2.5; equal to the rated boiler steam pressure 2.45MPa, the pressure is not less than 1.5. Dial gauge diameter of not less than 100 mm, to ensure that the operator can clearly see the surface pressure indication. 2. Steam boiler gauge plate should draw a red line that indicates the maximum allowable working pressure. 3. The steam boiler pressure gauge should be installed in place to facilitate the observation and purged, and should prevent high temperature, vibration and icing. 4. The steam boiler pressure gauge should be checked at least once every six months, after calibration seal should be sealed. 5. The steam boiler gauge connection tube not leak water and steam, otherwise it will reduce the pressure instruction value. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass hot water boiler, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. 6. A steam boiler pressure gauge measuring range should be compatible with the operating pressure of the device under test, the working pressure is generally 1.53 times, preferably 2 times the working pressure. Steam boiler no pressure gauge, pressure gauge or pressure gauge damage does not meet the requirements. When the steam boiler pressure gauge of the following circumstances, should stop using: 1, the surface of the glass broken or blurred dial; 2, lead-free seal, lead seal is broken or exceeds the calibration cycle; 3. When no pressure gauge pointer position is limited to the limit staple nail can not be restored, and the unlimited gauge pointer from zero rank bit data is out of range pressure layer. Difference; 4, leak or pointer jump table; 5, other defects affect the gauge accuracy.